KISS DP-558 Powersupply Modification


This page gives a step by step guide for modification of the KISS DP-558 Power Supply due to leaking/defective PSU capacitors.

The KISS DP-558 power supply has a construction error, that makes it fail, typically after beeing used 24/7 ranging from 1-3 years. The problem is proberly caused by the extensive heat that the unit generates combined low voltage capacitors (10 volt).

Mine failed after 2 years and 8 month beeing used 24/7.

Please observe, that making any modifications the the KISS DP-558 will void the warrenty, so proceed at own risk

KISS DP-558 is a high end harddisk recorder, with internet connection and FTP server and integrated online EPG (electronic Program Guide).

The DP-558 basically consist of a Powersupply unit, a main computer board, one DVD drive, one harddisk and a front unit

The harddisk is supplied by a +12 Volt (yellow) and +5 Volt (red). Ground is wired as black. When this type of error occures, both +12 volt and +5 volt linies drop in voltage. To make sure this fix is nessary for your type of error, check for the following symptoms:

Typical symptoms to look for:

  • LCD Displays only: "KISS DVD"
  • LCD Displays only: "BOOT ERR"
  • Harddisk does not spin up when unit is powered on
  • It is not possible to open DVD drive
  • No reaction to remote control
  • Display illumination is lower than usual
  • Capacitors C19,C20,C15 of PSU may show leakage
  • +12 volt and +5 volt supply to the KISS DP-558 harddisk is low (e.g 11 and 3 volt)


    Step by step guide to KISS DP-558 Power Supply Modification/Fix

    Step 1:
    Remove mains power line, and wait at least 30 minutes before any repair is started.
    Step 2:
    Remove cover of the unit.
    Step 3:
    Located the Power Supply Module (PSU). PSU Type mus be: Achme AM561B


    Step 4:
    Disconnet the 4 power connectors from PSU module

    Step 5:
    Remove the 4 screws mounting the PSU to chassie

    Step 6:
    Located capacitor C19,C20 and C15



    Step 7:
    Remove the Capacitors C19,C20 and C15



    Step 6:
    Replace the capacitors as followes (please observe polarity of capacitors +/-):
    C151000 uF 16V 105C (Type: WGR Radial, Low impedance)
    C192200 uF 16V 105C (Type: WGR Radial, Low impedance)
    C201000 uF 16V 105C (Type: WGR Radial, Low impedance)



    Step 9:
    Reassemble the unit.

    Final Note: it may be a good idea to replace other capacitors if they show sign of leakage. Please also note that a capacitor may be out of order even if it show not sign of leakage.


    Links


    [2007.05.02]
    (C) 2007 F.Larsen
    [HOME]
    Webhit on cbkn.dk





    Keywords: KISS DP-558 VCR. Linksys DP-558 VCR. HDD DEAD. BOOT ERR. KISS DVD. KISS BAD CAPS. KISS of Death. DP-558 HDD DEAD. DEAD powersupply. DP-558 Dead harddisk. DP-558 Dead HDD. DP-558 PSU FIX. DP-558 Cap Problem. Achme AM561B